E-ISSN 2305-1620 | ISSN 2221-0288
 

Original Article

Online Publishing Date:
30 / 05 / 2021

 


The impact of varying number of OSEM iterations on standardized uptake value and image quality of PET/CT scan

Babar Ali, Afshan Ashfaq, Muhammad Basim Kakakhel.


Abstract
Background: In positron emission tomography (PET) scan reporting, both quantitative and qualitative interpretations are used. Qualitative and quantitative interpretations depend upon PET/CT image quality that, along with many biological factors, strongly depends upon image reconstruction parameters. This study intends to evaluate one of the key reconstruction parameters, i.e., the number of reconstruction iterations on standardized uptake value (SUV) and the image quality of PET/CT scan.
Methods: Images of National Electrical Manufacturers Association International Electrotechnical Commission Image Quality Phantom (with a tumor to background ratio of 4:1 and 2-Fluoro-2-Deoxy-Gulocose as a radiotracer) were acquired on Discovery STE PET/CT scanner for acquisition time of 5 minutes. Acquired data were reconstructed using 2-7, 10, 15, and 20 ordered subset expectation maximization (OSEM) iterations of iterative reconstruction.
Results: Quantitative measure SUV and qualitative measure hot and cold lesion contrast, image's spatial resolution and background variability showed an increasing trend with OSEM iterations. A maximum increase in 20.25%, 16.33%, 9.79%, and 6.88% was observed in SUV for 10, 13, 17, and 22 mm lesions for OSEM iterations varying from 2 to 3. Percentage of hot lesion contrast showed a rapid increase as the number of iterations changed from 2 to 7 and increased slowly afterward. The percentage background variability showed an increasing trend for each lesion with OSEM iterations.
Conclusion: Optimized number of OSEM iterations is 3 with an image matrix size of 128 x 128 with filters full width at half maximum (FWHM) of 6 mm. High-resolution studies require three iterations with an image matrix size of 256 x 256 with filters FWHM of 6 mm. The extended reconstruction time limits the use of a higher number of iterations.

Key words: SUV, PET/CT, hot lesion contrast, cold lesion contrast, OSEM, iterations, FDG, background variability


 
ARTICLE TOOLS
Abstract
PDF Fulltext
How to cite this articleHow to cite this article
Citation Tools
Related Records
 Articles by Babar Ali
Articles by Afshan Ashfaq
Articles by Muhammad Basim Kakakhel
on Google
on Google Scholar


How to Cite this Article
Pubmed Style

Ali B, Ashfaq A, Kakakhel MB. The impact of varying number of OSEM iterations on standardized uptake value and image quality of PET/CT scan. Pak J Nucl Med. 2021; 11(1): 36-42. doi:10.24911/PJNMed.175-1599635121


Web Style

Ali B, Ashfaq A, Kakakhel MB. The impact of varying number of OSEM iterations on standardized uptake value and image quality of PET/CT scan. https://www.pjnmed.com/?mno=133041 [Access: February 28, 2024]. doi:10.24911/PJNMed.175-1599635121


AMA (American Medical Association) Style

Ali B, Ashfaq A, Kakakhel MB. The impact of varying number of OSEM iterations on standardized uptake value and image quality of PET/CT scan. Pak J Nucl Med. 2021; 11(1): 36-42. doi:10.24911/PJNMed.175-1599635121



Vancouver/ICMJE Style

Ali B, Ashfaq A, Kakakhel MB. The impact of varying number of OSEM iterations on standardized uptake value and image quality of PET/CT scan. Pak J Nucl Med. (2021), [cited February 28, 2024]; 11(1): 36-42. doi:10.24911/PJNMed.175-1599635121



Harvard Style

Ali, B., Ashfaq, . A. & Kakakhel, . M. B. (2021) The impact of varying number of OSEM iterations on standardized uptake value and image quality of PET/CT scan. Pak J Nucl Med, 11 (1), 36-42. doi:10.24911/PJNMed.175-1599635121



Turabian Style

Ali, Babar, Afshan Ashfaq, and Muhammad Basim Kakakhel. 2021. The impact of varying number of OSEM iterations on standardized uptake value and image quality of PET/CT scan. Pakistan Journal of Nuclear Medicine, 11 (1), 36-42. doi:10.24911/PJNMed.175-1599635121



Chicago Style

Ali, Babar, Afshan Ashfaq, and Muhammad Basim Kakakhel. "The impact of varying number of OSEM iterations on standardized uptake value and image quality of PET/CT scan." Pakistan Journal of Nuclear Medicine 11 (2021), 36-42. doi:10.24911/PJNMed.175-1599635121



MLA (The Modern Language Association) Style

Ali, Babar, Afshan Ashfaq, and Muhammad Basim Kakakhel. "The impact of varying number of OSEM iterations on standardized uptake value and image quality of PET/CT scan." Pakistan Journal of Nuclear Medicine 11.1 (2021), 36-42. Print. doi:10.24911/PJNMed.175-1599635121



APA (American Psychological Association) Style

Ali, B., Ashfaq, . A. & Kakakhel, . M. B. (2021) The impact of varying number of OSEM iterations on standardized uptake value and image quality of PET/CT scan. Pakistan Journal of Nuclear Medicine, 11 (1), 36-42. doi:10.24911/PJNMed.175-1599635121





Most Viewed Articles
Most Accessed Articles

  • Determination of the optimum filter for 99mTc SPECT breast imaging using a wire mesh collimator
    Xianling Dong, M I Saripan, R Mahmud, S Mashohor, Aihui Wang
    Pak J Nucl Med. 2017; 7(1): 9-15
    » Abstract » doi: 10.24911/PJNMed.7.2

  • Behaviour of wedges for different field sizes and depths
    Sajjad Ahmed Memon, Naeem Ahmed Laghari, Fayaz Hussain Mangi
    Pak J Nucl Med. 2017; 7(1): 20-27
    » Abstract » doi: 10.24911/PJNMed.7.4

  • Pre-operative cardiac risk stratification for noncardiac surgery in cancer patients using myocardial perfusion scintigraphy
    Iqbal Munir, Amrah Javaid, Khalid Nawaz, Mohammed Hathaf Al-Rowaily, Muaadh Abdualrehman Al-Asbahi
    Pak J Nucl Med. 2017; 7(1): 28-33
    » Abstract » doi: 10.24911/PJNMed.7.5

  • Clinical characteristics and long-term outcome of patients with differentiated carcinoma of thyroid with bone metastases: a retrospective study
    Sadaf Tufail Butt, Shazia Fatima, Noreen Marwat, Kahkashan Mir, Ayesha Ammar, Mohammad Faheem
    Pak J Nucl Med. 2017; 7(1): 34-37
    » Abstract » doi: 10.24911/PJNMed.7.6

  • A brief review of targetted radionuclide therapies
    Mohammed Hathaf Al-Rowaily, Daniele Dondi, MarcoChinol, Iqbal Munir, Muaadh Abdualrehman Alasbahi
    Pak J Nucl Med. 2017; 7(1): 4-8
    » Abstract » doi: 10.24911/PJNMed.7.1

  • Most Downloaded
    Top Downloaded Articles

  • Behaviour of wedges for different field sizes and depths
    Sajjad Ahmed Memon, Naeem Ahmed Laghari, Fayaz Hussain Mangi
    Pak J Nucl Med. 2017; 7(1): 20-27
    » Abstract » doi: 10.24911/PJNMed.7.4

  • Determination of the optimum filter for 99mTc SPECT breast imaging using a wire mesh collimator
    Xianling Dong, M I Saripan, R Mahmud, S Mashohor, Aihui Wang
    Pak J Nucl Med. 2017; 7(1): 9-15
    » Abstract » doi: 10.24911/PJNMed.7.2

  • Characterization of SIEMENS Symbia T SPECT camera in Monte Carlo simulation environment
    Xianling Dong, Mahmud Iqbal Saripan, Rozi Mahmud, Syamsiah Mashohor, Aihui Wang,
    Pak J Nucl Med. 2018; 8(1): 18-26
    » Abstract » doi: 10.24911/PJNMed.175-1540569779

  • A historic review of the discovery of the medical uses of radioiodine
    Barbara Hertz, Pushan Bharadwaj, Bennett Greenspan
    Pak J Nucl Med. 2020; 10(1): 60-63
    » Abstract » doi: 10.24911/PJNMed.175-1582813482

  • A brief review of targetted radionuclide therapies
    Mohammed Hathaf Al-Rowaily, Daniele Dondi, MarcoChinol, Iqbal Munir, Muaadh Abdualrehman Alasbahi
    Pak J Nucl Med. 2017; 7(1): 4-8
    » Abstract » doi: 10.24911/PJNMed.7.1

  • Most Cited Articles
    Most Cited Articles