Abstract
Background: In Nuclear Medicine, managing radioiodine (I-131) treated thyroid cancer patients remains challenging due to variations in global practices, regulatory criteria, and the need for individualized care. The lack of harmonization in patient release protocols has prompted the development of innovative, adaptive approaches.
Methods: This research introduces a novel artificial intelligence (AI)-based “Dynamic Patient Release Management System” designed to predict patient discharge timing using machine learning models. The system integrates patient-specific parameters (e.g., administered dose, biokinetics, contact scenarios, and socio-economic factors) while adhering to international safety standards. Approximately 350 patients treated with 50, 100, 150, and 200 mCi of I-131 were retrospectively analyzed to train and validate the model.
Result: The system reliably predicted safe discharge timelines: 1.5, 2.0, 2.5, and 3.0 days for 50, 100, 150, and 200 mCi doses, respectively. It also generated tailored recommendations for patient-specific occupancy factors, ensuring compliance with dose limits for caregivers and the public. Importantly, it allowed minor regional adaptability while maintaining regulatory compliance, particularly relevant for resource-limited settings.
Conclusion: The proposed AI model offers a personalized, safe, and flexible approach to managing I-131 patient release. It minimizes human judgment errors, standardizes practices across institutions, and supports policy implementation in diverse healthcare environments. This tool represents a significant advancement in balancing regulatory compliance with contextual needs.
Index Terms - AI patient release, Patient Release criteria of I-131, I-131 treated patient release via AI, one-click decision of patient
release.

Key words: Artificial Intelligence Patient Release, Iodine Radioisotopes, Radiation Protection, Patient Discharge, Radiation Dosage, Radiation Monitoring, Machine Learning, Clinical Decision Support Systems, Patient Release criteria of I-131vvia AI, one-click decision of patient release


 
ARTICLE TOOLS
Abstract
PDF Fulltext
How to cite this articleHow to cite this article
Citation Tools
Related Records
 Articles by Uzma Ilyas
Articles by Ghufran Ahmed
Articles by Hina Hashmi
Articles by Iftikhar Ahmad
Articles by Mohsin Raza
on Google
on Google Scholar


How to Cite this Article
Pubmed Style

Ilyas U, Ahmed G, Hashmi H, Ahmad I, Raza M. Development of an artificial intelligence-based dynamic release system for iodine (I-131) treated patients and close contact criteria. Pak J Nucl Med. 2025; 15(1): 03-16. doi:10.24911/PJNMed.175-1753789759


Web Style

Ilyas U, Ahmed G, Hashmi H, Ahmad I, Raza M. Development of an artificial intelligence-based dynamic release system for iodine (I-131) treated patients and close contact criteria. https://www.pjnmed.com/?mno=274073 [Access: January 11, 2026]. doi:10.24911/PJNMed.175-1753789759


AMA (American Medical Association) Style

Ilyas U, Ahmed G, Hashmi H, Ahmad I, Raza M. Development of an artificial intelligence-based dynamic release system for iodine (I-131) treated patients and close contact criteria. Pak J Nucl Med. 2025; 15(1): 03-16. doi:10.24911/PJNMed.175-1753789759



Vancouver/ICMJE Style

Ilyas U, Ahmed G, Hashmi H, Ahmad I, Raza M. Development of an artificial intelligence-based dynamic release system for iodine (I-131) treated patients and close contact criteria. Pak J Nucl Med. (2025), [cited January 11, 2026]; 15(1): 03-16. doi:10.24911/PJNMed.175-1753789759



Harvard Style

Ilyas, U., Ahmed, . G., Hashmi, . H., Ahmad, . I. & Raza, . M. (2025) Development of an artificial intelligence-based dynamic release system for iodine (I-131) treated patients and close contact criteria. Pak J Nucl Med, 15 (1), 03-16. doi:10.24911/PJNMed.175-1753789759



Turabian Style

Ilyas, Uzma, Ghufran Ahmed, Hina Hashmi, Iftikhar Ahmad, and Mohsin Raza. 2025. Development of an artificial intelligence-based dynamic release system for iodine (I-131) treated patients and close contact criteria. Pakistan Journal of Nuclear Medicine, 15 (1), 03-16. doi:10.24911/PJNMed.175-1753789759



Chicago Style

Ilyas, Uzma, Ghufran Ahmed, Hina Hashmi, Iftikhar Ahmad, and Mohsin Raza. "Development of an artificial intelligence-based dynamic release system for iodine (I-131) treated patients and close contact criteria." Pakistan Journal of Nuclear Medicine 15 (2025), 03-16. doi:10.24911/PJNMed.175-1753789759



MLA (The Modern Language Association) Style

Ilyas, Uzma, Ghufran Ahmed, Hina Hashmi, Iftikhar Ahmad, and Mohsin Raza. "Development of an artificial intelligence-based dynamic release system for iodine (I-131) treated patients and close contact criteria." Pakistan Journal of Nuclear Medicine 15.1 (2025), 03-16. Print. doi:10.24911/PJNMed.175-1753789759



APA (American Psychological Association) Style

Ilyas, U., Ahmed, . G., Hashmi, . H., Ahmad, . I. & Raza, . M. (2025) Development of an artificial intelligence-based dynamic release system for iodine (I-131) treated patients and close contact criteria. Pakistan Journal of Nuclear Medicine, 15 (1), 03-16. doi:10.24911/PJNMed.175-1753789759





Most Viewed Articles
Most Accessed Articles

  • Determination of the optimum filter for 99mTc SPECT breast imaging using a wire mesh collimator
    Xianling Dong, M I Saripan, R Mahmud, S Mashohor, Aihui Wang
    Pak J Nucl Med. 2017; 7(1): 9-15
    » Abstract » doi: 10.24911/PJNMed.7.2

  • Behaviour of wedges for different field sizes and depths
    Sajjad Ahmed Memon, Naeem Ahmed Laghari, Fayaz Hussain Mangi
    Pak J Nucl Med. 2017; 7(1): 20-27
    » Abstract » doi: 10.24911/PJNMed.7.4

  • Clinical characteristics and long-term outcome of patients with differentiated carcinoma of thyroid with bone metastases: a retrospective study
    Sadaf Tufail Butt, Shazia Fatima, Noreen Marwat, Kahkashan Mir, Ayesha Ammar, Mohammad Faheem
    Pak J Nucl Med. 2017; 7(1): 34-37
    » Abstract » doi: 10.24911/PJNMed.7.6

  • Pre-operative cardiac risk stratification for noncardiac surgery in cancer patients using myocardial perfusion scintigraphy
    Iqbal Munir, Amrah Javaid, Khalid Nawaz, Mohammed Hathaf Al-Rowaily, Muaadh Abdualrehman Al-Asbahi
    Pak J Nucl Med. 2017; 7(1): 28-33
    » Abstract » doi: 10.24911/PJNMed.7.5

  • A brief review of targetted radionuclide therapies
    Mohammed Hathaf Al-Rowaily, Daniele Dondi, MarcoChinol, Iqbal Munir, Muaadh Abdualrehman Alasbahi
    Pak J Nucl Med. 2017; 7(1): 4-8
    » Abstract » doi: 10.24911/PJNMed.7.1

  • Most Downloaded
    Top Downloaded Articles

  • Behaviour of wedges for different field sizes and depths
    Sajjad Ahmed Memon, Naeem Ahmed Laghari, Fayaz Hussain Mangi
    Pak J Nucl Med. 2017; 7(1): 20-27
    » Abstract » doi: 10.24911/PJNMed.7.4

  • Determination of the optimum filter for 99mTc SPECT breast imaging using a wire mesh collimator
    Xianling Dong, M I Saripan, R Mahmud, S Mashohor, Aihui Wang
    Pak J Nucl Med. 2017; 7(1): 9-15
    » Abstract » doi: 10.24911/PJNMed.7.2

  • Characterization of SIEMENS Symbia T SPECT camera in Monte Carlo simulation environment
    Xianling Dong, Mahmud Iqbal Saripan, Rozi Mahmud, Syamsiah Mashohor, Aihui Wang,
    Pak J Nucl Med. 2018; 8(1): 18-26
    » Abstract » doi: 10.24911/PJNMed.175-1540569779

  • A historic review of the discovery of the medical uses of radioiodine
    Barbara Hertz, Pushan Bharadwaj, Bennett Greenspan
    Pak J Nucl Med. 2020; 10(1): 60-63
    » Abstract » doi: 10.24911/PJNMed.175-1582813482

  • A brief review of targetted radionuclide therapies
    Mohammed Hathaf Al-Rowaily, Daniele Dondi, MarcoChinol, Iqbal Munir, Muaadh Abdualrehman Alasbahi
    Pak J Nucl Med. 2017; 7(1): 4-8
    » Abstract » doi: 10.24911/PJNMed.7.1