Abstract
Aims: This work is intended to establish the effect of ambulatory patients undergoing positron emission tomography (PET) imaging on a sensitive gamma counter that is located within the nuclear medicine department and used for in-vitro tests in the department. <br><br> Methods: The effect on gamma counts recorded by a stationary 68Ge positron source and of a PET patient (100 minutes post injection of 550 MBq 18F-2-deoxy-D-glucose) walking past the Perkin Elmer WIZARD2 2470 gamma counter's shielded laboratory was measured. Further tests using uniform 68Ge sources both inside and outside the gamma counter laboratory were performed with a 99mTc glomerular filtration rate gamma counting protocol. <br><br> Results: The stationary 68Ge sources could be detected by the gamma counter during both a GFR counting protocol and an open energy window protocol at all distances tested, both inside and outside of the shielded laboratory. A single PET patient walking past the laboratory had a negligible effect on an open counting window. <br><br> Conclusions: The potential effects of PET patients on the WIZARD2 gamma counter can be mitigated by ensuring these patients are encouraged to exit the department after their scan without lingering outside the shielded laboratory in the Nuclear Medicine department.


 
ARTICLE TOOLS
Abstract
PDF Fulltext
How to cite this articleHow to cite this article
Citation Tools
Related Records
 Articles by Anne Marie Stapleton
Articles by Michael A Masoomi
Articles by Nicole Pratt-Boyden
Articles by Lesley Sanders
on Google
on Google Scholar

How to Cite this Article
Pubmed Style

Anne Marie Stapleton, Michael A Masoomi, Nicole Pratt-Boyden, Lesley Sanders. Impact of positron emissions from injected patients on in vitro test results. Pak J Nucl Med. 2015; 5(1): 22-27.


Web Style

Anne Marie Stapleton, Michael A Masoomi, Nicole Pratt-Boyden, Lesley Sanders. Impact of positron emissions from injected patients on in vitro test results. https://www.pjnmed.com/?mno=284643 [Access: February 28, 2024].


AMA (American Medical Association) Style

Anne Marie Stapleton, Michael A Masoomi, Nicole Pratt-Boyden, Lesley Sanders. Impact of positron emissions from injected patients on in vitro test results. Pak J Nucl Med. 2015; 5(1): 22-27.



Vancouver/ICMJE Style

Anne Marie Stapleton, Michael A Masoomi, Nicole Pratt-Boyden, Lesley Sanders. Impact of positron emissions from injected patients on in vitro test results. Pak J Nucl Med. (2015), [cited February 28, 2024]; 5(1): 22-27.



Harvard Style

Anne Marie Stapleton, Michael A Masoomi, Nicole Pratt-Boyden, Lesley Sanders (2015) Impact of positron emissions from injected patients on in vitro test results. Pak J Nucl Med, 5 (1), 22-27.



Turabian Style

Anne Marie Stapleton, Michael A Masoomi, Nicole Pratt-Boyden, Lesley Sanders. 2015. Impact of positron emissions from injected patients on in vitro test results. Pakistan Journal of Nuclear Medicine, 5 (1), 22-27.



Chicago Style

Anne Marie Stapleton, Michael A Masoomi, Nicole Pratt-Boyden, Lesley Sanders. "Impact of positron emissions from injected patients on in vitro test results." Pakistan Journal of Nuclear Medicine 5 (2015), 22-27.



MLA (The Modern Language Association) Style

Anne Marie Stapleton, Michael A Masoomi, Nicole Pratt-Boyden, Lesley Sanders. "Impact of positron emissions from injected patients on in vitro test results." Pakistan Journal of Nuclear Medicine 5.1 (2015), 22-27. Print.



APA (American Psychological Association) Style

Anne Marie Stapleton, Michael A Masoomi, Nicole Pratt-Boyden, Lesley Sanders (2015) Impact of positron emissions from injected patients on in vitro test results. Pakistan Journal of Nuclear Medicine, 5 (1), 22-27.





Most Viewed Articles
Most Accessed Articles

  • Determination of the optimum filter for 99mTc SPECT breast imaging using a wire mesh collimator
    Xianling Dong, M I Saripan, R Mahmud, S Mashohor, Aihui Wang
    Pak J Nucl Med. 2017; 7(1): 9-15
    » Abstract » doi: 10.24911/PJNMed.7.2

  • Behaviour of wedges for different field sizes and depths
    Sajjad Ahmed Memon, Naeem Ahmed Laghari, Fayaz Hussain Mangi
    Pak J Nucl Med. 2017; 7(1): 20-27
    » Abstract » doi: 10.24911/PJNMed.7.4

  • Pre-operative cardiac risk stratification for noncardiac surgery in cancer patients using myocardial perfusion scintigraphy
    Iqbal Munir, Amrah Javaid, Khalid Nawaz, Mohammed Hathaf Al-Rowaily, Muaadh Abdualrehman Al-Asbahi
    Pak J Nucl Med. 2017; 7(1): 28-33
    » Abstract » doi: 10.24911/PJNMed.7.5

  • Clinical characteristics and long-term outcome of patients with differentiated carcinoma of thyroid with bone metastases: a retrospective study
    Sadaf Tufail Butt, Shazia Fatima, Noreen Marwat, Kahkashan Mir, Ayesha Ammar, Mohammad Faheem
    Pak J Nucl Med. 2017; 7(1): 34-37
    » Abstract » doi: 10.24911/PJNMed.7.6

  • A brief review of targetted radionuclide therapies
    Mohammed Hathaf Al-Rowaily, Daniele Dondi, MarcoChinol, Iqbal Munir, Muaadh Abdualrehman Alasbahi
    Pak J Nucl Med. 2017; 7(1): 4-8
    » Abstract » doi: 10.24911/PJNMed.7.1

  • Most Downloaded
    Top Downloaded Articles

  • Behaviour of wedges for different field sizes and depths
    Sajjad Ahmed Memon, Naeem Ahmed Laghari, Fayaz Hussain Mangi
    Pak J Nucl Med. 2017; 7(1): 20-27
    » Abstract » doi: 10.24911/PJNMed.7.4

  • Determination of the optimum filter for 99mTc SPECT breast imaging using a wire mesh collimator
    Xianling Dong, M I Saripan, R Mahmud, S Mashohor, Aihui Wang
    Pak J Nucl Med. 2017; 7(1): 9-15
    » Abstract » doi: 10.24911/PJNMed.7.2

  • Characterization of SIEMENS Symbia T SPECT camera in Monte Carlo simulation environment
    Xianling Dong, Mahmud Iqbal Saripan, Rozi Mahmud, Syamsiah Mashohor, Aihui Wang,
    Pak J Nucl Med. 2018; 8(1): 18-26
    » Abstract » doi: 10.24911/PJNMed.175-1540569779

  • A historic review of the discovery of the medical uses of radioiodine
    Barbara Hertz, Pushan Bharadwaj, Bennett Greenspan
    Pak J Nucl Med. 2020; 10(1): 60-63
    » Abstract » doi: 10.24911/PJNMed.175-1582813482

  • A brief review of targetted radionuclide therapies
    Mohammed Hathaf Al-Rowaily, Daniele Dondi, MarcoChinol, Iqbal Munir, Muaadh Abdualrehman Alasbahi
    Pak J Nucl Med. 2017; 7(1): 4-8
    » Abstract » doi: 10.24911/PJNMed.7.1

  • Most Cited Articles
    Most Cited Articles